Swiss VECTOR VITECTOR SDC2/SOC2 Integrated Controller SDC2-16-THCQ-210.102U-MOD-1 Detailed Content
Optional temperature, relative humidity, CO₂ or VOC sensors available upon request
MODBUS RTU/ASCII 485 or BACnet MS/TP communication
Based on RS485 communication, can communicate with remote operation terminals OPA2-VC or OPT1
2 loops, universal PI control and switching control, applicable to any analog and digital signal processing
Up to 2 analog outputs, 1 single/double relay output and one passive input
Multiple auxiliary functions: Heating-cooling automatic switching, automatic, setpoint compensation, etc.
Energy-saving control for heating or cooling based on temperature
Can calculate difference, average, minimum and maximum values of multiple inputs
Can calculate dew point and enthalpy
Cascade control
8 freely configurable alarm conditions, output status can be selected under alarm conditions
Input signal and setpoint transmission function
Function, setpoint offset
User parameters and control parameters programmable with password protection
7-day programmable schedule, setpoints can be changed in the schedule, and outputs can be manually positioned directly
(Note: Since SDC2/SOC2 does not include a real-time clock, time needs to be synchronized every 24 hours if using the schedule function)
Supports parameter backup, optional accessory AEC-PM2, easily copied to multiple controllers
Free PC parameter configuration software provided: EasySet Controller
| Model Name | Model Code | Description/Options |
| SDC2-16-T-200.101U-1 | 40-300169 | Single temperature input, 1 single/double relay; 1 analog output |
| SDC2-16-T-200.101U-MOD-1 | 40-300170 | Single temperature input, 1 single/double relay; 1 analog output; Modbus 485 |
| SDC2-16-T-200.101U-BAC-1 | 40-300160 | Single temperature input, 1 single/double relay; 1 analog output; BACnet MSTP |
| SDC2-16-C-200.101U-1 | 40-300167 | Single CO₂ input, 1 single/double relay; 1 analog output |
| SDC2-16-THQ-200.101U-1 | 40-300168 | Temperature, humidity and VOC input, 1 single/double relay; 1 analog output |
| SDC2-16-TH-210.102U-1 | 40-300171 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input |
| SDC2-16-TH-210.102U-MOD-1 | 40-300172 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; Modbus 485 |
| SDC2-16-TH-210.102U-BAC-1 | 40-300166 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; BACnet MSTP |
| SDC2-16-THCQ-210.102U-1 | 40-300164 | Temperature, humidity, CO₂, VOC input, 1 single/double relay; 2 analog outputs; 1 external passive input |
| SDC2-16-THC-210.102U-MOD-1 | 40-300174 | Temperature, humidity, CO₂ input, 1 single/double relay; 2 analog outputs; 1 external passive input; Modbus 485 |
| SDC2-16-THC-210.102U-BAC-1 | 40-300173 | Temperature, humidity, CO₂ input, 1 single/double relay; 2 analog outputs; 1 external passive input; BACnet MSTP |
| SDC2-16-THQ-210.102U-MOD-1 | 40-300162 | Temperature, humidity, VOC input, 1 single/double relay; 2 analog outputs; 1 external passive input; Modbus 485 |
| SDC2-16-THQ-210.102U-BAC-1 | 40-300161 | Temperature, humidity, VOC input, 1 single/double relay; 2 analog outputs; 1 external passive input; BACnet MSTP |
| SDC2-16-THCQ-210.102U-MOD-1 | 40-300165 | Temperature, humidity, CO₂ and VOC input, 1 single/double relay; 2 analog outputs; 1 external passive input; Modbus 485 |
| SDC2-16-THCQ-210.102U-BAC-1 | 40-300163 | Temperature, humidity, CO₂ and VOC input, 1 single/double relay; 2 analog outputs; 1 external passive input; BACnet MSTP |
| SOC2-16-TH-210.102U-1 | 40-300181 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input |
| SOC2-16-TH-210.102U-BAC-1 | 40-300182 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; BACnet MSTP |
| SOC2-16-TH-210.102U-MOD-1 | 40-300183 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; Modbus 485 |
| SOC2-16-TH-210.102U-OP-1 | 40-300184 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; with display |
| SOC2-16-TH-210.102U-OP-BAC-1 | 40-300185 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; with display; BACnet MSTP |
| SOC2-16-TH-210.102U-OP-MOD-1 | 40-300186 | Temperature and humidity input, 1 single/double relay; 2 analog outputs; 1 external passive input; with display; Modbus 485 |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | VECTOR |
| Spec: | SDC2-16-T-200.101U-1 |
| Stock: | |
| Origin: | China / Shanghai / Xingqu |